Kalstein

Understanding the Consumables, Spare Parts, and Accessories for the YR01806 Conductivity Meter

By Kalstein · Published on:

Category:articulos-de-productos

Understanding the Consumables, Spare Parts, and Accessories for the YR01806 Conductivity Meter

Dive deep into the world of consumables, spare parts, and accessories compatible with the YR01806 Conductivity Meter, ensuring optimal performance and longevity

Understanding the Consumables, Spare Parts, and Accessories for the YR01806 Conductivity Meter

Understanding the Consumables, Spare Parts, and Accessories for the YR01806 Conductivity Meter

The YR01806 Conductivity Meter is designed for precision and accuracy in measuring conductivity, TDS, salinity, and resistivity. To maintain peak performance of your device, it is crucial to understand the consumables, spare parts, and accessories that are compatible. This article provides a detailed overview of what you need to know to keep your YR01806 in optimal condition.

Technical Specifications of the YR01806

ModelYR01806
BrandKalstein
CategoryConductivity Meter
SubcategoryPortable Conductivity Meter
Price (USD)149.00
Price (EUR)100
Net Weight
Gross Weight1 Kg
Dimensions(65×120×31)mm
Shipping Size(460×300×55)mm

Key Consumables Required for the YR01806

Using the YR01806 effectively requires specific consumables that enhance its functionality.

  • Calibration Solutions: 1, 2, or 3-point calibration solutions are essential for ensuring that your readings are accurate. The YR01806 automatically recognizes 25 buffer solutions for calibration.
  • Electrodes: The device is compatible with various conductivity electrodes (K=1) that meet the measurement accuracy requirements ranging from 0.5μS/cm to 200mS/cm.
  • Cleaning Solutions: Regular cleaning solutions are necessary to maintain electrode performance and reliability.

Spare Parts for the YR01806

In the event of wear and tear, having access to spare parts ensures your YR01806 remains operational.

  • Replacement Electrodes: Replacement electrodes should be on hand, particularly if frequent use is expected or if measurements vary significantly.
  • Batteries: The YR01806 operates with two AA batteries (1.5V x2). Always have a spare set to avoid interruptions in use.
  • Protective Cases: To prolong the life of the device, protective cases are recommended for safe storage and transport.

Recommended Accessories

Accessories can enhance the functionality of the YR01806, making it more suitable for specific applications.

  • Data Logger: A compatible data logger can help store and analyze data collected from the YR01806.
  • Protective Glasses: When working in environments where splashes can occur, protective eyewear is advisable.
  • Tripod Stands: For consistent readings, especially in laboratory settings, tripod stands can provide stability.

Compatibility Table for Consumables and Accessories

Consumable/AccessoryCode/ModelReplacement Interval
Calibration SolutionsCalibration Kit YR01806-CKEvery 3 months
Replacement ElectrodesElectrode YR01806-EEvery 6 months
BatteriesAA Batteries (1.5V)As needed
Protective CaseYR01806-CaseAs needed

Frequently Asked Questions

What calibration options are available for the YR01806?

The YR01806 offers automatic recognition of 25 buffer solutions with options for calibration using 1, 2, or 3 points, ensuring accurate readings across various measurements.

How often should I replace the electrodes of the YR01806?

It is recommended to replace the electrodes every 6 months, depending on usage frequency and the accuracy of readings observed.

What are the key specifications of the YR01806?

The YR01806 features a measuring range for conductivity from 0.5μS/cm to 200mS/cm, automatic temperature compensation, and a large LCD display for easy reading.

Can I use the YR01806 in different environmental conditions?

Yes, the YR01806 is designed to operate in a temperature range of 0 to 100°C and can function effectively in various humidity levels, making it suitable for multiple environments.

What should I do if I encounter an error code?

Check the user manual for troubleshooting steps based on the specific error code. Common issues may include calibration errors or low battery warnings.

Are there any specific cleaning solutions recommended for the YR01806?

It is advisable to use specialized cleaning solutions that are safe for the electrodes to maintain their performance and prolong their lifespan.

How can I request a quote for consumables or accessories for the YR01806?

You can request a quote for consumables or accessories by contacting us through our sales channels, ensuring you have officially compatible items for your YR01806.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Pocket Conductivity Meter °C/°F YR01806 with all specifications, dimensions, accessories and quote options.
View product datasheet →