Epoxy-Coated Steel Basic Chemical Laboratory Fume Extraction Hood YR05811
The Epoxy-Coated Steel Basic Chemical Laboratory Fume Extraction Hood YR05811 is designed to ensure a safe and efficient working environment in laboratories handling hazardous chemicals. This fume hood combines advanced engineering and high-quality materials to provide optimal ventilation and safety for laboratory personnel. With an epoxy-coated steel exterior, this device not only fulfills functional requirements but also stands the test of time against corrosive chemicals.
Product Description
The fume extraction hood YR05811 is engineered with various features aimed at enhancing laboratory safety and functionality. Key components include:
- Front panel for easy access
- 5 mm thick melamine-coated guide liners and deflectors
- 5 mm tempered glass window for visibility
- Exclusive PP laboratory vessel
- Built-in drainage tube for easy waste management
- Bottom side panels and back panels for structural integrity
- Integrated axial fan, air collector, and corrosion-resistant hose
- Wind regulator for adjustable airflow
- Upper side panel made of 1.2 mm thick galvanized steel, epoxy-coated on the outside
- Built-in LED tube lighting
- Fan and lamp switch for convenience
- Multifunction splash-proof socket
- Solid corrosion-resistant core, 12.7 mm physical and chemical board, work table
- Door frames and door panels for easy access
The fume extraction hood YR05811 is designed to improve air quality while minimizing exposure to harmful fumes and vapors in a laboratory setting.
Market Price
The market price for the Epoxy-Coated Steel Basic Chemical Laboratory Fume Extraction Hood YR05811 is approximately $508.00 USD. Below is a technical comparison of the YR05811 with other models in the same range:
| Model | External Size (mm) | Internal Size (mm) | Work Surface Height (mm) | Max Window Opening (mm) | Airflow Speed (m/s) | Noise Level (dB) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| YR05808 | 650 x 650 x 1000 | 450 x 600 x 750 | 800 | 750 | 0.4-0.6 | ≤60 | 110 |
| YR05809 | 800 x 650 x 1000 | 600 x 600 x 750 | 800 | 750 | 0.4-0.6 | ≤60 | 110 |
| YR05810 | 1000 x 650 x 1000 | 800 x 600 x 750 | 800 | 750 | 0.4-0.6 | ≤60 | 115 |
| YR05811 | 1000 x 650 x 1000 | 1000 x 600 x 750 | 800 | 750 | 0.4-0.6 | ≤60 | 120 |
| YR05812 | 1500 x 650 x 1000 | 1300 x 600 x 750 | 800 | 750 | 0.4-0.6 | ≤60 | 130 |
Frequently Asked Questions
What is a fume extraction hood used for?
A fume extraction hood is used to safely capture and remove harmful fumes, vapors, and particles generated during laboratory procedures, protecting users from exposure to hazardous substances.
How does the YR05811 ensure safety in the laboratory?
The YR05811 features an integrated ventilation system that maintains optimal airflow, reducing the risk of inhaling toxic fumes. Its durable construction also provides resistance to corrosive chemicals.
What are the dimensions of the YR05811?
The external dimensions are 1000 x 650 x 1000 mm, and the internal dimensions are 1000 x 600 x 750 mm.
Is the YR05811 suitable for all types of chemicals?
This fume hood is designed to handle a wide variety of chemicals, particularly acids and strong alkalis, making it versatile for many laboratory applications.
What kind of maintenance does the YR05811 require?
Regular checks on the ventilation system and cleaning of surfaces are essential for maintaining the efficiency and safety of the fume hood. It is also important to ensure that the fan and lighting systems are functioning properly.
Can the height of the front window be adjusted?
Yes, the front window of the YR05811 is manually adjustable, allowing users to customize the opening based on their specific needs and safety requirements.
How can I request a quote for the YR05811?
To request a quote for the YR05811, please visit our website where you can find detailed information and a simple form to fill out.
Pros and Cons
Understanding the advantages and disadvantages of the Epoxy-Coated Steel Basic Chemical Laboratory Fume Extraction Hood YR05811 is crucial for informed decision-making:
- Pros:
- High resistance to corrosive substances due to epoxy coating.
- Integrated ventilation system enhances air quality.
- Adjustable front window allows for versatility in use.
- Includes LED lighting for better workspace visibility.
- Cons:
- Initial cost may be high for some laboratories.
- Requires regular maintenance to ensure optimal performance.
Field Usage
The YR05811 is ideal for various laboratory settings, including:
- Chemical analysis laboratories
- Pharmaceutical research centers
- Academic institutions for teaching and research purposes
- Industrial laboratories handling hazardous materials
Its robust design and reliable safety features make it a favorite among professionals needing to ensure a safe working environment while conducting experiments.
Recommendations
When considering the purchase of the YR05811, we recommend evaluating your specific laboratory needs, including the type of chemicals you work with, the required airflow, and space constraints. Additionally, ensure that your staff is trained in the proper use of fume hoods for maximum safety and efficiency.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.