Kalstein

Horizontal Pulsating Vacuum Autoclave with Automatic Vertical Sliding Door YR05648: Buying Criteria and Validation

By Kalstein · Published on:

Category:articulos-de-productos

Horizontal Pulsating Vacuum Autoclave with Automatic Vertical Sliding Door YR05648: Buying Criteria and Validation

Discover the essential buying criteria and validation process for the Horizontal Pulsating Vacuum Autoclave YR05648, featuring an automatic vertical sliding doo

Horizontal Pulsating Vacuum Autoclave with Automatic Vertical Sliding Door YR05648: Buying Criteria and Validation

Horizontal Pulsating Vacuum Autoclave with Automatic Vertical Sliding Door YR05648: Buying Criteria and Validation

Product Description

The Horizontal Pulsating Vacuum Autoclave YR05648 is designed to disinfect and sterilize objects using saturated steam. Its horizontal structure relies on electric heating, ensuring efficient performance. This autoclave consists of a sterilization chamber, casing, jacket, door, steam generator, vacuum system, cooling system, piping system, control system, display system, and power supply system.

This model is widely used in Central Sterile Supply Departments (CSSD), laboratories, scientific research institutions, pharmaceuticals, and the food industry. It is suitable for high-temperature and high-pressure-resistant items, including unwrapped or wrapped instruments, dressings, rubber, liquids, porous articles, and hollow instruments that require sterilization.

Market Price

ModelPrice (USD)Price (EUR)Weight (kg)Dimensions (cm)Packaging (cm)
YR056489531.001850180055 x 55 x 70140 x 135 x 195

Frequently Asked Questions

What is the primary function of the Horizontal Pulsating Vacuum Autoclave YR05648?

The primary function of the Horizontal Pulsating Vacuum Autoclave YR05648 is to disinfect and sterilize various instruments and materials using saturated steam under high pressure and temperature. This ensures that all contaminants are effectively eliminated, making it ideal for medical and laboratory applications.

What are the operating temperature and pressure ranges for this autoclave?

The YR05648 operates within a temperature range of 105℃ to 139℃ and has a working pressure range of 0 to 0.25Mpa. This versatility allows it to cater to different sterilization needs across various industries.

How does the vacuum system benefit the sterilization process?

The vacuum system of the YR05648 enhances the sterilization process by effectively removing air from the chamber before steam penetration. This ensures better steam distribution, reducing the chances of heat and steam entrapment in the materials being sterilized.

What safety features are integrated into the YR05648 model?

This model comes equipped with multiple safety features, including a low water cut-off sensor, overpressure protection devices, and mechanisms that prevent the door from opening when the chamber is under pressure. These features ensure safe operation and protect both the equipment and the users.

Can this autoclave be used for various types of materials?

Yes, the YR05648 is suitable for a wide range of materials, including textiles, rubber, liquids, and porous items. It can sterilize both wrapped and unwrapped instruments, making it versatile for different sterilization requirements.

What certifications does the YR05648 hold?

The Horizontal Pulsating Vacuum Autoclave YR05648 is certified under multiple standards, including CE, ISO9001, ISO13485, ASME, IEC60601-1, and FDA. These certifications ensure that the equipment meets international safety and quality standards.

Pros and Cons

Pros

  • Automatic vertical sliding door for easy access.
  • High-temperature and pressure reliability suitable for diverse materials.
  • Integrated PLC + HMI control system for user-friendly operation.
  • Robust safety features ensure secure operation.
  • High efficiency vacuum system enhances sterilization effectiveness.

Cons

  • Higher initial investment compared to traditional autoclaves.
  • Requires regular maintenance and monitoring to ensure optimal performance.
  • Size may be a limitation in smaller laboratories.

Field Usage

The Horizontal Pulsating Vacuum Autoclave YR05648 finds extensive usage in various fields:

  • Medical Sector: Used for sterilizing surgical instruments, tools, and other medical devices.
  • Pharmaceutical Industry: Essential for sterilizing production equipment and ensuring that products meet safety standards.
  • Laboratories: Ideal for sterilizing laboratory equipment, glassware, and biological materials.
  • Food Industry: Utilized in sterilizing food containers and equipment to prevent contamination.

Recommendations

When considering the purchase of the Horizontal Pulsating Vacuum Autoclave YR05648, it is essential to evaluate the specific needs of your organization:

  • Assess the volume of materials that require sterilization on a daily basis.
  • Investigate the compatibility of the autoclave with the types of materials you intend to sterilize.
  • Consider the available space in your facility to accommodate the autoclave.
  • Review the warranty and support services offered by the manufacturer.

If you are interested in obtaining a quote for the YR05648 or want more information on our range of products, please do not hesitate to reach out to us.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Horizontal Pulsating Vacuum Autoclave Automatic Vertical Sliding Door YR05648 with all specifications, dimensions, accessories and quote options.
View product datasheet →