Kalstein

Biological safety cabinet YR06538 // YR06542

SKU:YR06538 · By Kalstein

Category:Laminar flow hood, clean bench and biosecurity cabinet

Biological safety cabinet YR06538 // YR06542

Biological safety cabinet YR06538 // YR06542 — equipo de laboratorio Kalstein con especificaciones técnicas, características avanzadas y soluciones profesionales certificadas para uso científico.

The biological safety cabinet, models YR06538 and YR06542, is a cutting-edge solution designed to protect personnel, products, and the environment, thanks to its negative pressure system that prevents leaks. It uses a principle of 70% internal circulation and 30% external discharge. The structure is constructed of high-quality cold-rolled steel and the work surface is made of corrosion-resistant physical-chemical plate. CNC laser precision cutting and electrostatic epoxy resin spray surface treatment ensure durability. The system incorporates intelligent control with an LCD touch panel that allows intuitive understanding of the operating status. The cabinets comply with the international standard ISO14644.1 Class 5 (equivalent to US Federal 209E, Class 100). Motor: Adopts the German EBM motor with high air volume and low energy consumption, optimized to reduce turbulence concentration and ensure airflow uniformity. Filtration: Equipped with external HEPA high-efficiency filters and downward ULPA ultra-high-efficiency filters.

Frequently Asked Questions

What is the difference between ULPA and HEPA filters? The G series uses ultra-high efficiency ULPA filters (99.999% efficiency), while the D series uses high efficiency HEPA filters (99.995% efficiency). Both are excellent, but ULPA offers a slightly higher level of purity. What is the precision of downward airflow control? The precision of downward airflow control is 0.015 m/s, which ensures flow uniformity and stability to maintain sterility within the work area. What sizes are available? What level of cleanliness does the cabinet guarantee? The cabinet guarantees Level 5 of the international standard ISO14644.1 (Class 100 US Federal 209E), a strict requirement for sensitive environments.

Advantages and Disadvantages

Advantages: Double Filtration: Uses external HEPA filters and ULPA/HEPA downflow filters, guaranteeing up to 99.999% efficiency. Superior Safety (Negative Pressure): The negative pressure design prevents leaks, protecting the operator and the environment. Optimized Design: Reasonable air duct and optimized negative pressure box for flow uniformity. High-Performance German Motor: Uses low-consumption, high-air-volume EBM motor. Durable Construction: Corrosion-resistant cold-rolled steel and epoxy resin surface treatment. Disadvantages: Environmental Requirements: The working environment must be maintained between 10-30°C and relative humidity below 70%. Shipping Weight: The shipping weight is considerable, ranging from 138 kg to 198 kg (depending on size), which can complicate transportation and installation. Flow Limitations: Although it is recirculating (70% internal), the 30% external discharge requires consideration of an exhaust ventilation system.

Product Use in the Field

The Class II Type A2 Biosafety Cabinet is indispensable for handling low to moderate risk biological agents, such as viruses, bacteria, and cell cultures, which require biosafety. It is the standard choice in microbiology laboratories, hospitals, biotechnology and pharmaceutical research centers where product, personnel, and environmental protection is critical. Its vibration control capability (half-peak: 3μm) and stable airflow are essential for sensitive experiments.

Recommendations

To ensure longevity and maximum safety: Perform regular maintenance on the filters and check the calibration of the imported sensor. Confirm that the working environment meets the temperature (10-30°C) and humidity (below 70%) requirements. Periodically check the inlet flow velocity (average 0.53m/s to 0.56m/s) and downward airflow velocity (average 0.35m/s) to ensure that negative pressure protection remains effective. Use heavy-duty mobile casters for initial positioning and ensure stability before operation.

Technical Specifications

ModeloYR06538YR06539YR06540YR06541YR06542
Package Size (mm)110*100*140130*100*140160*100*140190*100*140210*100*140
External Size (mm)900*760*22501100*760*22501300*760*22501500*760*22501800*760*2250
Internal Size (mm)740*600*600940*600*6001140*600*6001340*600*6001640*600*600
LightLámpara fluorescente LED a prueba de tres condiciones
Work surfaceAcero inoxidable cepillado SUS304 #
CasingPlaca de acero laminado en frío de 1.0 mm de grosor con recubrimiento de resina epoxi en la superficie
FanVentilador incorporado 220V, 138W, diámetro 250mm
Technical parameters of high efficiency
Window5mm tempered glass
Illumination and UVUV disinfection lamp * 1, LED lamp 10W * 2.
Outlets$10text{A}$ waterproof socket * 2, installed on the back wall.
Voltage$220text{V}/50text{HZ}$
Filtration and VentilationEquipped with HEPA filter * 2, built-in 300W centrifugal fan.
Air Flow30% air exhaust, 70% air recirculation.
Control PanelLCD digital control panel.
PackagingFull packaging, with hard cardboard and wooden box.
MobilityHeavy duty castors.

Technical specifications

ManufacturerKalstein

Frequently asked questions

How to know the prices of Biological safety cabinet YR06538 // YR06542?

To know the price of Biological safety cabinet YR06538 // YR06542, please send us an email with your request through the contact form AQUI.

What are the delivery times for Biological safety cabinet YR06538 // YR06542?

Delivery time depends on stock availability and freight type (air or sea). In stock: air 15-30 days, sea 45-60 days. Out of stock: air 30-60 days, sea 60-90 days.

How to make a purchase of Biological safety cabinet YR06538 // YR06542?

You can buy by email ([email protected]), phone (+33 (0) 1 70 39 26 50) or through the official Kalstein website in your country.

How does the warranty work for Biological safety cabinet YR06538 // YR06542?

All Kalstein equipment comes with a 1-year warranty against manufacturing defects. The warranty does not cover damage from improper installation or misuse. See our «terms and conditions» AQUI.

Can I request a quote online for Biological safety cabinet YR06538 // YR06542?

Yes, you can request a quote for the Kalstein equipment you are interested in directly from our official website. Click AQUI.