The Biosafety Cabinet Class II A2 YR0090-A is a top-tier laboratory apparatus engineered to ensure utmost safety for lab workers, the environment, and sample integrity. This advanced biosafety cabinet features a sophisticated air curtain isolation design that prevents cross-contamination by discharging 30% of the airflow while circulating 70% within. The negative pressure vertical laminar flow system enhances safety without the need for additional piping. Equipped with a movable glass door, the cabinet allows for flexible operations while providing complete closure during sterilization. The incorporation of HEPA filters ensures a high level of protection, making this cabinet ideal for handling low to moderate risk biological agents often encountered in medical, pharmaceutical, and research laboratories.

Market Price

Typically, the Class II A2 biosafety cabinets range from $2500 to $3300 in the market. This range reflects the inclusion of various cutting-edge features such as waterproof sockets, built-in UV lamp protection devices, and advanced filtration systems that contribute to the safe manipulation of biological agents.

Frequently Asked Questions

  • What is the main purpose of a Class II A2 biosafety cabinet? A Class II A2 biosafety cabinet is designed to protect the user, the environment, and the samples being handled from exposure to harmful biological agents.
  • Can the UV lamp be used with the safety door open? No, the UV lamp can only be operated when the safety door is completely closed, ensuring maximum safety during sterilization processes.
  • What kind of maintenance is required? Regular checks on HEPA filters and ensuring the interior surfaces are cleaned and disinfected routinely are recommended for optimal operation.

Advantages and Disadvantages

Advantages: This biosafety cabinet offers superior protection with its HEPA filters and negative pressure environment, is easy to clean thanks to its 304 stainless steel interior, and features an ergonomic design for user convenience. Disadvantages: The need for regular maintenance checks on filters and mechanical parts could be seen as a potential downside for some users.

Product Use in the Field

In practical scenarios, the Class II A2 Biosafety Cabinet is pivotal in processes like cell and tissue culture, handling potentially infectious samples, and conducting research that demands a sterile and contained environment. Its role in minimizing contamination risks makes it indispensable in both research labs and industrial applications.

Recommendations

To maximize the performance of the Biosafety Cabinet Class II A2 YR0090-A, users are advised to regularly inspect the HEPA filters, maintain an orderly workspace within the cabinet, and follow strict sterilization protocols with each use. For specific technical support or further inquiries, consider requesting a quote through Kalstein Plus, where you can also access our user-friendly automatic quotation tool for your convenience.

Features

  • Air curtain isolation for superior cross-contamination prevention
  • Adjustable, lockable glass door for enhanced operational flexibility
  • Environmentally responsible with high-quality 304 stainless steel construction
  • HEPA-filtered interior and exhaust for maximal protection
  • Equipped with an LED LCD control panel and UV lamp protection
  • Portable and compact design suitable for varied laboratory setups
Technical Specification
ModelYR0090-A
Cleanliness gradeClass 100@≥0.5μm (U.S. Federal 209E)
Number of colonies≤0.5pcs/dish·hour (Φ90mm culture plate)
Average wind speedInside the door0.38±0.025m/s
Middle0.26±0.025m/s
Inside0.27±0.025m/s
Front suction air speed0.55m±0.025m/s
Noise≤65dB(A)
Vibration half peak≤5μm
Power supplyAC 220V/50Hz
Maximum power consumption600W
Weight140KG
Internal Size (mm)W×D×H600×500×520
External Size (mm) W×D×H760×650×1230
High efficiency filter specification and quantity560×440×50×1
380×380×50×1
Specification and quantity of fluorescent lamp/UV lamp8W×1/20W×1

Technical specifications

Weight130 kg
ManufacturerKalstein

Video Biosafety Cabinet Class II A2 YR0090-A

Frequently asked questions

How to know the prices of Biosafety Cabinet Class II A2 YR0090-A?

To know the price of Biosafety Cabinet Class II A2 YR0090-A, please send us an email with your request through the contact form AQUI.

What are the delivery times for Biosafety Cabinet Class II A2 YR0090-A?

Delivery time depends on stock availability and freight type (air or sea). In stock: air 15-30 days, sea 45-60 days. Out of stock: air 30-60 days, sea 60-90 days.

How to make a purchase of Biosafety Cabinet Class II A2 YR0090-A?

You can buy by email ([email protected]), phone (+33 (0) 1 70 39 26 50) or through the official Kalstein website in your country.

How does the warranty work for Biosafety Cabinet Class II A2 YR0090-A?

All Kalstein equipment comes with a 1-year warranty against manufacturing defects. The warranty does not cover damage from improper installation or misuse. See our «terms and conditions» AQUI.

Can I request a quote online for Biosafety Cabinet Class II A2 YR0090-A?

Yes, you can request a quote for the Kalstein equipment you are interested in directly from our official website. Click AQUI.