Technical Performance and Safety of the YR06671 Tunnel Phototherapy System
The YR06671 Tunnel Phototherapy System is a cutting-edge medical solution specifically designed for the effective treatment of jaundice in newborns. By rapidly lowering bilirubin levels, this equipment significantly reduces the yellowing of the skin in neonates, ensuring high-efficiency therapeutic effects. It is primarily aimed at neonatal intensive care units (NICUs) and pediatrics departments that require a technology that combines quick recovery with maximum patient safety.
Product Description
This device stands out due to its 360° irradiation design without dead angles, allowing for uniform and extensive coverage over the baby's body to maximize treatment effectiveness. It incorporates an LED (Light Emitting Diode) light source with adjustable intensity at three levels (33%, 66%, and 100%) and an effective wavelength range of 400nm to 550nm. Among its technological innovations are:
Automatic Temperature Adjustment System: Keeps the patient in an optimal thermal environment throughout the process.
Visual and Operational Safety: Equipped with a 360° alarm light for the operator to instantly recognize alerts and an additional white LED bulb to clearly visualize the patient's skin color without interrupting therapy.
Adaptable Ergonomics: Offers optional electric lift feet to adjust the tunnel height according to medical staff needs.
Market Price
| Specification | Features |
|---|---|
| Model | YR06671 |
| Light Source | LED (Light Emitting Diode) |
| Effective Wavelength | 400nm - 550nm |
| Irradiation Intensity | Adjustable (33%, 66%, 100%) |
| Maximum Irradiance (Upper) | 3600 μw/cm² |
| Maximum Irradiance (Lower) | 3200 μw/cm² |
| Effective Irradiation Area | 400mm x 250mm |
| Irradiation Uniformity | > 0.4 |
| Lift Stroke Range | 0 - 200mm |
| Power Supply | AC 100V - 240V |
| Power Consumption | ≤ 250VA |
| Safety Alarms | Temperature, End of treatment, Bed extraction |
| Packing Dimensions | 98 x 65 x 115 cm (Approximate according to industrial standard) |
| Equipment Weight | Approx. 65 kg (Net) / 85 kg (Gross with packaging) |
Frequently Asked Questions
What is the lifespan of the lighting system?
The device features an accumulated usage time display range of up to 49,999 hours, ensuring a long operational durability.
What happens if the bed is removed during treatment?
The system automatically detects when the bed is removed and suspends the treatment to ensure safety.
Is it compatible with different voltages?
Yes, its power supply supports a wide range of AC 100V to 240V.
How is the device cleaned and maintained?
The baby cabin is designed in an orderly manner to facilitate cleaning and disinfection.
What safety features are included?
It includes alarms for temperature, treatment completion, and bed extraction to ensure continuous patient safety.
Can the irradiation intensity be adjusted for different cases?
Yes, the system allows the selection of three intensity levels depending on the severity of the jaundice.
What is the effective irradiation area for the device?
The effective irradiation area measures 400mm x 250mm, which is suitable for standard neonates.
Pros and Cons
Pros:
Comprehensive Treatment: Uniform 360° irradiation that accelerates bilirubin breakdown.
Intensity Control: Allows selection among three irradiance levels based on case severity.
Easy Maintenance: The baby cabin is designed for easy cleaning and disinfection.
Smart Alerts: Includes end-of-treatment reminders via voice and text.
Cons:
Power Consumption: Requires a power input of ≤250VA, which should be considered in the electrical planning of the unit.
Size Limitation: The effective irradiation area is 400mm x 250mm, suitable for standard neonates.
Field Usage
The YR06671 is ideal for use in specialized clinics, maternal and child hospitals, and high-complexity health centers. Its operation is recommended by trained personnel who can monitor the alarm ranges for skin temperature (33°C to 38.5°C) and the box (16°C to 42°C) established by the device. For optimal operation, ensure that the temperature sensor is properly placed and that the cabin is securely closed so that the automatic temperature adjustment system functions accurately.
Recommendations
For healthcare professionals seeking an effective solution for treating neonatal jaundice, the YR06671 Tunnel Phototherapy System is a top-notch choice. Its advanced features, safety mechanisms, and adaptability offer significant advantages in critical care settings. When considering the purchase of this device, it is advisable to request a quote and explore financing options to make the acquisition feasible for your healthcare facility.
Request a quote today to discover how the YR06671 can enhance your neonatal care capabilities.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.