Technical Performance and Security of YR04991 Circulating Bathroom Cooling and Heating System
The YR04991 Circulating Bathroom Cooling and Heating System is designed to maintain a liquid environment at a constant temperature ranging from -40 °C to 100 °C. This advanced system is ideal for temperature control in various scientific applications, including electronic component testing, chemical synthesis, and life sciences experiments.
Product Description
The YR04991 model provides a reliable solution with its PID temperature control, overheating alarm, and low water level alarm functionalities. The system incorporates high-efficiency compressor cooling technology that ensures low noise levels and eliminates the use of fluorine, making it an environmentally friendly option.
Noteworthy attributes of the YR04991 include:
- PID Temperature Control: Ensures precise temperature management.
- Overheating Alarm: Alerts users to prevent potential hazards.
- Low Water Level Alarm: Prevents damage by ensuring adequate water levels.
- High-Efficiency Compressor: Operates quietly while maintaining performance.
- Robust Pump Flow and Pressure: Facilitates efficient circulation.
- Stainless Steel Tank: Constructed with 304 stainless steel for durability.
- Open Design: Allows for tank experiments and easy access.
Market Price
The YR04991 Circulating Bathroom Cooling and Heating System is competitively priced at approximately $733.00 USD or €1466, reflecting its advanced features and reliability in temperature control.
| Feature | YR04991 | YR04990 |
|---|---|---|
| Temperature Range (°C) | -5 to 100 | -40 to 100 |
| Flow Rate (l/min) | 20 | 10 |
| Pump Head (m) | 12 | 10 |
| Capacity (L) | 210 x 210 | 160 x 140 |
| Dimensions (WxDxH) | 500 x 400 x 820 | 450 x 360 x 820 |
Frequently Asked Questions
What applications can the YR04991 Circulating System be used for?
The YR04991 Circulating System is suitable for various applications, including temperature control for electronic component testing, chemical synthesis, and life sciences experiments.
What is the temperature control range of the YR04991?
The YR04991 can maintain a temperature range from -5 °C to 100 °C.
How does the safety alarm system work?
The system includes an overheating alarm and a low water level alarm that alert the user to prevent any operational hazards.
What materials are used in the construction of the tank?
The tank is made from high-quality 304 stainless steel, ensuring durability and resistance to corrosion.
Is the YR04991 system energy efficient?
Yes, the YR04991 utilizes a high-efficiency compressor that minimizes energy consumption while providing effective cooling and heating.
What is the flow rate of the circulating pump?
The circulating pump has a flow rate of 20 liters per minute, ensuring efficient fluid circulation.
How can I request a quote for the YR04991 Circulating System?
You can easily request a quote for the YR04991 by contacting our sales team through our website.
Pros and Cons
Pros
- Wide temperature range from -5 °C to 100 °C.
- Efficient PID control for precise temperature management.
- Equipped with safety alarms for overheating and low water levels.
- Robust construction using stainless steel for longevity.
- Quiet operation with low noise levels.
Cons
- Initial investment can be high compared to basic systems.
- Requires regular maintenance to ensure optimal performance.
Field Usage
The YR04991 Circulating Bathroom Cooling and Heating System is widely used in various fields of research and industrial applications. Its temperature precision makes it ideal for laboratories involved in:
- Electronic component testing, where controlled environments are crucial.
- Chemical synthesis, requiring precise temperature regulation for reactions.
- Life sciences experiments, including biological studies that need stable temperature conditions.
- Quality control processes in manufacturing, ensuring products meet strict specifications.
- Climate simulation studies, where temperature variation plays a key role.
Recommendations
For optimal performance and longevity of the YR04991 system, it is recommended to:
- Conduct regular maintenance checks to ensure all components function effectively.
- Utilize the system within its specified temperature and flow rate limits.
- Keep the tank clean and free from impurities to avoid damage to internal components.
- Ensure proper installation according to manufacturer guidelines for safety and efficiency.
- Train staff adequately on the operation and safety features of the system.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.